Date: Mon, 10 Apr 2000 07:25:23 +0000 (GMT) From: Didier Derny <didier@omnix.net> To: Oscar Ricardo Silva <oscars@mail.utexas.edu> Cc: questions@freebsd.org Subject: Re: DLT Autoloader on FreeBSD 3.4? Message-ID: <Pine.BSF.3.96.1000410072319.22918B-100000@omnix.net> In-Reply-To: <4.2.2.20000407122058.00a959a0@mail.utexas.edu>
next in thread | previous in thread | raw e-mail | index | archive | help
we have two overland libraries here working with FreeBSD 3.4, one lxm and one lxs. it works without any problem after having activated the driver for the changer in the kernel (ch0). we are not using amanda. On Fri, 7 Apr 2000, Oscar Ricardo Silva wrote: > We just purchase an Overland Data MiniLibraryXpress DLT 7000 Autoloader > (model: DLT-LXMS7115) that we will use with Amanda to run our > backups. The drive is a single-ended SCSI-2 device with the DLT drive > itself and the loader mechanism existing as two SCSI devices on the same > bus. Although the host operating system hasn't been decided yet, it will > probably be FreeBSD 3.4. > > I'm curious if anybody is using this type of hardware with this version of > the OS? Any potential problems? Any suggestions on where I can find more > information? > > > Thanks, > > Oscar > oscars@mail.utexas.edu > > > > "Don't believe the hype" > > > > To Unsubscribe: send mail to majordomo@FreeBSD.org > with "unsubscribe freebsd-questions" in the body of the message > To Unsubscribe: send mail to majordomo@FreeBSD.org with "unsubscribe freebsd-questions" in the body of the message
Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?Pine.BSF.3.96.1000410072319.22918B-100000>