Date:      Fri, 22 Mar 2002 10:37:55 +1030
From:      Greg 'groggy' Lehey <grog@FreeBSD.org>
To:        Kris Kirby <kris@catonic.net>
Cc:        freebsd-questions@freebsd.org
Subject:   Re: Vinum, "stale" disk.
Message-ID:  <20020322103755.K69857@wantadilla.lemis.com>
In-Reply-To: <Pine.BSF.4.33.0203220003290.98037-100000@spaz.catonic.net> <20020322102037.G69857@wantadilla.lemis.com>
References:  <20020322102037.G69857@wantadilla.lemis.com> <Pine.BSF.4.33.0203220003290.98037-100000@spaz.catonic.net> <Pine.BSF.4.33.0203211623190.37252-100000@spaz.catonic.net> <20020322102037.G69857@wantadilla.lemis.com>

next in thread | previous in thread | raw e-mail | index | archive | help
On Friday, 22 March 2002 at  0:04:58 +0000, Kris Kirby wrote:
> On Friday, 22 March 2002 at 10:20:37 +1030, Greg 'groggy' Lehey wrote:
>> On Thursday, 21 March 2002 at 16:25:52 +0000, Kris Kirby wrote:
>>>
>>> # vinum l
>>>
>>> 3 drives:
>>> D a                     State: up	Device /dev/ad1s1e	Avail: 1/19469 MB (0%)
>>> D b                     State: up	Device /dev/ad2s1e	Avail: 1/19469 MB (0%)
>>> D c                     State: up	Device /dev/ad3s1e	Avail: 1/19469 MB (0%)
>>>
>>> 1 volumes:
>>> V raid0                 State: up	Plexes:       1	Size:         38 GB
>>>
>>> 1 plexes:
>>> P raid0.p0           R5 State: degraded	Subdisks:     3	Size:         38 GB
>>>
>>> 3 subdisks:
>>> S raid0.p0.s0           State: up	PO:        0  B Size:         19 GB
>>> S raid0.p0.s1           State: stale	PO:      273 kB Size:         19 GB
>>> S raid0.p0.s2           State: up	PO:      546 kB Size:         19 GB
>>>
>>> #uname -a
>>> FreeBSD kickme.huntsvilleal.com 4.3-STABLE FreeBSD 4.3-STABLE #0: Fri May  4 02:14:02 GMT 2001     root@kickme.huntsvilleal.com:/usr/src/sys/compile/TUCOWS  i386
>>>
>>> How can I force vinum to update drive .s1 without comprimising the
>>> integrety of the data on the other two drives?
>>
>> The simple answer: you can't.  This is a non-resilient configuration,
>> and it's no longer consistent.
>
> I don't understand;
>
>>> 1 plexes:
>>> P raid0.p0 R5 State: degraded Subdisks:  3 Size:  38 GB
>
> Leads me to believe this is a RAID5 system.

Oops, sorry, too early in the morning.  Why do you call a RAID-5
volume raid0?

 # vinum start raid0.p0

I see there's another thread in the mail this morning about problems
reviving RAID-5 plexes.  You should probably wait until I've checked
it out.

Greg
--
When replying to this message, please copy the original recipients.
If you don't, I may ignore the reply.
For more information, see http://www.lemis.com/questions.html