Date:      Tue, 24 Jul 2001 13:46:46 -0500
From:      Bob Martin <bob@buckhorn.net>
To:        Odhiambo Washington <wash@wananchi.com>
Cc:        FBSD-ISP <freebsd-isp@FreeBSD.org>
Subject:   Re: Another Favor request with RADIUS
Message-ID:  <3B5DC296.2004DE71@buckhorn.net>
References:  <20010724202805.B90847@everest.wananchi.com>

next in thread | previous in thread | raw e-mail | index | archive | help
Odhiambo Washington wrote:
> 
> With the vast amount of experience available on this list, I hope someone
> has at least used some proprietary software called EXTENT RBS (For
> ISPs) and some legacy equipment from Livingston called Portmaster 2E.
> 
> I've spent most of my life with Portmaster 2E and was whistling all the
> way home when my boss decide that we can now advance to Cisco Access
> Servers. Due to some emergency my boss dumped another Portmaster 2E and a
> USR Modem rack into my office. Being the boss he says there are 20 phone
> lines lying idle and what I need to do is to get the portmaster accepting
> dialins.
> 
> Now I run this RBS Stuff (sorry, it only runs on Linux) and it works
> superb with the Cisco 3600 Access Servers.
> 
> Not with the portmaster. I am not inexperienced with the Portmaster but
> this one has gotten me stumped. When I do test runs, the modems handshake
> okay but authentication fails. I have configured the Portmaster well, with
> a share secret btn it and the RBS Radius Server. I've also read the RBS
> manual once again and exhausted all pages talking about the Livingston
> product. Nothing shows even on the logs for the RBS Radius server.
> 
> I am suspecting a port mismatch between the Portmaster and the RBS.
> While that is simple suspicion, I've read some very nice portmaster
> manuals at www.express.ru/docs/ but still can't seem to find a setting to
> change the port the Portmaster is using to communicate. My memory seems to
> have fast faded but I think the portmaster uses port 1645 UDP for radius
> auth. Can someone verify this? RBS uses port 1812 (auth) and 1813
> (accounting). Portmaster has ComOS 3.5 but I can upgrade.
> 
> I need some help, if someone has any ideas.
> 
> MTIA
> 
> -Wash
> 
Your PM2's use the old numbers, 1645/1646
IIRC, the PM Console software will let you change this.
-- 
Bob Martin, CTO
InterNet Unlimited
http://www.inu.net
mailto:bob@inu.net

To Unsubscribe: send mail to majordomo@FreeBSD.org
with "unsubscribe freebsd-isp" in the body of the message