Date: Sat, 3 Jan 1998 11:56:03 -0500 From: Norman C Rice <nrice@emu.sourcee.com> To: freebsd-questions@FreeBSD.ORG Subject: UPSD toggle wraparound and negative response Message-ID: <19980103115603.07099@emu.sourcee.com>
next in thread | raw e-mail | index | archive | help
I am running the experimental upsd port on several FreeBSD 2.2.5-STABLE systems with APC Smart-UPS 1000s. Every 10 minutes /var/log/messages receives entries similar to Jan 3 11:17:38 emu upsd[231]: apc_tune: toggle wraparound Jan 3 11:17:39 emu upsd[231]: apc_tune: toggle wraparound Jan 3 11:17:39 emu upsd[231]: apc_tune: negative response: NO Jan 3 11:17:40 emu upsd[231]: apc_tune: toggle wraparound The `apc_tune: negative response: NO' message also appears on the console. I believe the frequency of these messages is due to the every 600 { tune "high-transfer-point" 264 tune "low-transfer-point" 196 tune "line-alarm" "0" tune "line-sensitivity" "L" tune "low-batteries-duration" 2 tune "nominal-voltage" 220 tune "shutdown-delay" 20 tune "wakeup-batteries-capacity" 25 tune "wakeup-delay" 0 # tune "batteries-replaced" "01/01/77" # tune "label" "WildWind" } section in /etc/upsd.conf. My experiments with removal of line power indicate that the shutdown process and line restoration work properly. For the time being, I have commented out these messages in apc.c. What do these messages mean? Do they indicate a problem that needs fixing for proper operation? Are there other programs that work with the APC Smart-UPS? -- Regards, Norman C. Rice, Jr.