Date:      Fri, 26 Jan 2007 14:18:01 +1100 (EST)
From:      Bruce Evans <bde@zeta.org.au>
To:        Robin Gruyters <r.gruyters@yirdis.nl>
Cc:        freebsd-net@freebsd.org
Subject:   Re: [Fwd: Re: bge Ierr rate increase from 5.3R -> 6.1R]
Message-ID:  <20070126141754.X7697@besplex.bde.org>
In-Reply-To: <20070125170532.c9c2374hkwk4oc4k@server.yirdis.net>
References:  <20070125170532.c9c2374hkwk4oc4k@server.yirdis.net>

next in thread | previous in thread | raw e-mail | index | archive | help
On Thu, 25 Jan 2007, Robin Gruyters wrote:

> On 13-Jan-2007 Oleg Bulyzhin wrote:
>> 
>> > Could you please test attached patch? It should fix ierrs issue and 
>> should not
>> > break link events (would be fine to test it: unplug/plug cable, try to 
>> change
>> > media with ifconfig, change media on other end of wire).
>
> Just wondering will this patch/update be available for RELENG_6? I have the 
> same problems here with 3 of our servers.
> ...
> And here the netstat interface statistics:
> [...]
> Name    Mtu Network       Address              Ipkts Ierrs    Opkts Oerrs 
> Coll
> ...
> bge0   1500 <Link#5>      00:12:79:94:ed:12 11343768 2114510 20564242     0 
> 0
> bge1*  1500 <Link#6>      00:12:79:94:ed:11        0     0        0     0 
> 0

I think the bug fixed by the patch couldn't cause so many errors (unless
Ipkts has overflowed and the uptime more than a week).

Bruce