I'm reopening this old topic.  Stefan's mail dated 9 Nov is quoted in
full at the end.

I happened to try `iozone 900 65536' on a fresh 1GB partition (on the
3rd quarter of a 4G Grand Prix drive with a BT445C controller) mounted
with -o async, and noticed that writing is much slower:

	3206878 bytes/second for writing the file
	5106987 bytes/second for reading the file

The sync results are:

	4880600 bytes/second for writing the file
	5105829 bytes/second for reading the file

In old mail, I said that the slowdown is because -o async unavoidably
writes in a bad order, and that this didn't matter a lot because it
mainly affects stupid benchmarks such as iozone.  Now I think that
slowdown is because of concurrency problems, not because of a bad order.
With -o async, almost all writes are delayed a relatively long time.
Huge sequential writes result in the buffer cache becoming full of dirty
buffers.  These are written one at a time in LRU order in getblk().  LRU
order is ideal for huge sequential writes, but getblk() has to wait a
lot for free buffers.  For non-sequential writes, a cache full of dirty
buffers causes bad ordering too.

Writing dirty buffers in blkno order when the cache becomes too dirty
should work better.  sync() should do something similar when a buffer
has been dirty for too long.  It's important to write nearby dirty
buffers if writing them has a low cost (if clustering is done at a
lower level and the drive[r] doesn't combine commands, then writing
an extra buffer might reduce the number of writes and have a negative
cost!).  Because of this, sorting shouldn't be left to the hardware -
the hardware can't optimize for buffers that will be written 30
seconds later.

Bruce

>On Nov 8, 16:12, Boyd Faulkner wrote:
>} Subject: iozone and mount -o async

>} With my Maxtor 235M SCSI 1 drive mounted normally
>} 
>} iozone 32 gives

>} IOZONE performance measurements:
>}         804903 bytes/second for writing the file
>}         1112974 bytes/second for reading the file
>} 
>} mounted with -o async

>} IOZONE performance measurements:
>}         714042 bytes/second for writing the file
>}         1115575 bytes/second for reading the file

>I'm seeing slower writes, too, and surprisingly 
>by about the same absolute amount (some 100KB/s).

>My "iozone 32" results are:

>se@x14> tail -3 /tmp/sync.io 
>IOZONE performance measurements:
>        2529427 bytes/second for writing the file
>        4446135 bytes/second for reading the file
>se@x14> tail -3 /tmp/async.io 
>IOZONE performance measurements:
>        2422429 bytes/second for writing the file
>        4423241 bytes/second for reading the file


>Bonnie gives significantly different results, too:

>              -------Sequential Output-------- ---Sequential Input-- --Random--
>              -Per Char- --Block--- -Rewrite-- -Per Char- --Block--- --Seeks---
>Machine    MB K/sec %CPU K/sec %CPU K/sec %CPU K/sec %CPU K/sec %CPU  /sec %CPU
>sync      100  1505 98.6  3267 31.2  2167 42.3  1656 98.5  5929 72.1  78.4  9.2
>async     100  1425 96.4  2661 24.3  2077 41.7  1644 98.0  5923 72.1  78.9  9.1


>All tests on the half ful inner (slower) half of my 
>2GB Atlas driven by an ASUS SP3G, 486DX2/66, NCR SCSI.


>Regards, STefan

>-- 