Date: Sun, 14 Dec 2008 12:56:56 +0000 (UTC) From: Ruslan Ermilov <ru@FreeBSD.org> To: src-committers@freebsd.org, svn-src-all@freebsd.org, svn-src-head@freebsd.org Subject: svn commit: r186079 - head/sbin/atacontrol Message-ID: <200812141256.mBECuu0E059473@svn.freebsd.org>
next in thread | raw e-mail | index | archive | help
Author: ru Date: Sun Dec 14 12:56:56 2008 New Revision: 186079 URL: http://svn.freebsd.org/changeset/base/186079 Log: Fix the fallouts from r146267: - Add the forgotten "mode" argument to the "mode" command. - Move the description of "info" to where it belongs. Modified: head/sbin/atacontrol/atacontrol.8 Modified: head/sbin/atacontrol/atacontrol.8 ============================================================================== --- head/sbin/atacontrol/atacontrol.8 Sun Dec 14 11:48:51 2008 (r186078) +++ head/sbin/atacontrol/atacontrol.8 Sun Dec 14 12:56:56 2008 (r186079) @@ -25,7 +25,7 @@ .\" .\" $FreeBSD$ .\" -.Dd June 25, 2008 +.Dd December 14, 2008 .Dt ATACONTROL 8 .Os .Sh NAME @@ -63,6 +63,7 @@ .Nm .Ic mode .Ar device +.Op Ar mode .Nm .Ic info .Ar channel @@ -94,7 +95,7 @@ The .Ar channel argument is the ATA channel device (e.g., ata0) on which to operate. The following commands are supported: -.Bl -tag -width "rebuild" +.Bl -tag -width ".Ic addspare" .It Ic attach Attach an ATA .Ar channel . @@ -162,9 +163,13 @@ Rebuild a RAID1 array on a RAID capable .It Ic status Get the status of an ATA RAID. .It Ic mode -Without the mode argument, the current transfer modes of the +Without the +.Ar mode +argument, the current transfer mode of the device are printed. -If the mode argument is given, the ATA driver +If the +.Ar mode +argument is given, the ATA driver is asked to change the transfer mode to the one given. The ATA driver will reject modes that are not supported by the hardware. @@ -190,13 +195,12 @@ and .Cm UDMA6 (alias .Cm UDMA133 ) . -The device name and manufacture/version strings are shown. .It Ic cap Show detailed info about the device on .Ar device . .It Ic spindown Set or report timeout after which the -.Ar device +.Ar device will be spun down. To arm the timeout the device needs at least one more request after setting the timeout. @@ -205,6 +209,7 @@ No further actions are needed in this ca .It Ic info Show info about the attached devices on the .Ar channel . +The device name and manufacture/version strings are shown. .It Ic list Show info about all attached devices on all active controllers. .El @@ -312,7 +317,7 @@ If the system has a pure software array RAID controller, then shut the system down, make sure that the disk that was still working is moved to the bootable position (channel 0 or whatever the BIOS allows the system to boot from) and the blank disk -is placed in the secondary position, then boot the system into +is placed in the secondary position, then boot the system into single-user mode and issue the command: .Pp .Dl "atacontrol addspare ar0 ad6"
Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?200812141256.mBECuu0E059473>