Date: Tue, 26 Jul 2016 18:24:38 -0700 (PDT) From: Don Lewis <truckman@FreeBSD.org> To: brde@optusnet.com.au Cc: freebsd-net@freebsd.org Subject: Re: IPv6 -> IPv4 fallback broken in serf, kernel bug? Message-ID: <201607270124.u6R1OcTi082647@gw.catspoiler.org> In-Reply-To: <201607262340.u6QNes2t082436@gw.catspoiler.org>
next in thread | previous in thread | raw e-mail | index | archive | help
After giving this some more thought, I believe that the read and write wakeups are correct when the connection attempt fails. I also think that read() should return ENOTCONN if the socket never got to the connected state. I'm not sure how write() should behave. The Open Group Base Specifications Issue 7 says: [ECONNRESET] A write was attempted on a socket that is not connected. [EPIPE] A write was attempted on a socket that is shut down for writing, or is no longer connected. In the latter case, if the socket is of type SOCK_STREAM, a SIGPIPE signal shall also be sent to the thread. whereas our man page only mentions EPIPE. I think poll() should set POLLERR and not POLLIN or POLLOUT if the connection attempt fails. I think kqueue is fine, but the poll() emulation in apr should map the connection failure into POLLERR.