Skip site navigation (1)Skip section navigation (2)
Date:      Fri, 09 Sep 2022 02:10:04 +0000
From:      bugzilla-noreply@freebsd.org
To:        fs@FreeBSD.org
Subject:   [Bug 264141] nvme(4): Heavy load to SSD wedges 13.1 system: Controller in fatal status, resetting ... Resetting controller due to a timeout and possible hot unplug.
Message-ID:  <bug-264141-3630-4uvJElGu0o@https.bugs.freebsd.org/bugzilla/>
In-Reply-To: <bug-264141-3630@https.bugs.freebsd.org/bugzilla/>

index | next in thread | previous in thread | raw e-mail

https://bugs.freebsd.org/bugzilla/show_bug.cgi?id=264141

--- Comment #27 from Masachika ISHIZUKA <ish@amail.plala.or.jp> ---
(In reply to crb from comment #25)

I'm using two HP proliant N54L and ADATA XPG SX6000 Lite M.2 2280 PCIe Gen3x4
SSD 256GB (with 64MB host memory buffer). These ssd are
hmpre=hmmin=16384(64MB). The same thing are occuring about two month intervals.
Both machine are used ssd for zfs ZIL/L2ARC on FreeBSD 13.1R. I installed these
SSDs on 13.0R and they never happend more than 6 months.

I don't think hp proliant server has poor power supply and I think you cannot
judge with 2 days.

-- 
You are receiving this mail because:
You are the assignee for the bug.
You are on the CC list for the bug.

help