Skip site navigation (1)Skip section navigation (2)
Date:      Sun, 2 Oct 2005 13:09:39 +0200
From:      Stijn Hoop <stijn@win.tue.nl>
To:        Rob Pitt <rob@motionpath.com>
Cc:        freebsd-questions@freebsd.org
Subject:   Re: GVINUM woes
Message-ID:  <20051002110939.GD86786@pcwin002.win.tue.nl>
In-Reply-To: <5972D23F-E849-4927-ABEC-538C533A7046@motionpath.com>
References:  <5972D23F-E849-4927-ABEC-538C533A7046@motionpath.com>

next in thread | previous in thread | raw e-mail | index | archive | help
On Sun, Oct 02, 2005 at 12:55:34AM +0100, Rob Pitt wrote:
> Hello,
> 
> When I power into single user mode and rebuild all my stale plesks  
> (start root.p1, etc) it works fine they all come back up everyone is  
> up until I reboot and then...
> 
> ad4: 76293MB <Maxtor 6Y080M0/YAR51HW0> [155009/16/63] at ata2-master  
> SATA150
> ad6: 76293MB <Maxtor 6Y080M0/YAR51HW0> [155009/16/63] at ata3-master  
> SATA150
> GEOM_MIRROR: Device gm0 created (id=2565216261).
> GEOM_MIRROR: Device gm0: provider ad6 detected.
> GEOM_MIRROR: Device gm0: provider ad6 activated.
> GEOM_MIRROR: Device gm0: provider mirror/gm0 launched.
> GEOM_VINUM: subdisk swap.p1.s0 state change: down -> stale
> GEOM_VINUM: subdisk root.p1.s0 state change: down -> stale
> GEOM_VINUM: subdisk tmp.p1.s0 state change: down -> stale
> GEOM_VINUM: subdisk var.p1.s0 state change: down -> stale
> GEOM_VINUM: subdisk usr.p1.s0 state change: down -> stale

Why do you have both GEOM_MIRROR and GEOM_VINUM loaded? They cannot share
the same provider.

--Stijn

-- 
My server has more fans than Britney.
		-- Steve Warwick, from a posting at questions@freebsd.org



Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?20051002110939.GD86786>