Date: Sun, 18 Mar 2018 22:36:21 +0000 (UTC) From: Eitan Adler <eadler@FreeBSD.org> To: src-committers@freebsd.org, svn-src-all@freebsd.org, svn-src-stable@freebsd.org, svn-src-stable-11@freebsd.org Subject: svn commit: r331150 - stable/11/share/man/man7 Message-ID: <201803182236.w2IMaLpF048520@repo.freebsd.org>
next in thread | raw e-mail | index | archive | help
Author: eadler Date: Sun Mar 18 22:36:21 2018 New Revision: 331150 URL: https://svnweb.freebsd.org/changeset/base/331150 Log: MFC r325215,r325216: Update tuning(7) some more At this point its unclear how much help tuning(7) is whatsoever but leave it around in case someone decides to spend some time on it. Modified: stable/11/share/man/man7/tuning.7 Directory Properties: stable/11/ (props changed) Modified: stable/11/share/man/man7/tuning.7 ============================================================================== --- stable/11/share/man/man7/tuning.7 Sun Mar 18 22:29:41 2018 (r331149) +++ stable/11/share/man/man7/tuning.7 Sun Mar 18 22:36:21 2018 (r331150) @@ -23,7 +23,7 @@ .\" .\" $FreeBSD$ .\" -.Dd March 22, 2017 +.Dd October 30, 2017 .Dt TUNING 7 .Os .Sh NAME @@ -41,8 +41,7 @@ Configuring too little swap can lead to inefficiencies in the VM page scanning code as well as create issues later on if you add more memory to your machine. On larger systems -with multiple SCSI disks (or multiple IDE disks operating on different -controllers), configure swap on each drive. +with multiple disks, configure swap on each drive. The swap partitions on the drives should be approximately the same size. The kernel can handle arbitrary sizes but internal data structures scale to 4 times the largest swap partition. @@ -176,11 +175,6 @@ This means you want to use a large off-center stripe size such as 1152 sectors so sequential I/O does not seek both disks and so meta-data is distributed across both disks rather than concentrated on a single disk. -If -you really need to get sophisticated, we recommend using a real hardware -RAID controller from the list of -.Fx -supported controllers. .Sh SYSCTL TUNING .Xr sysctl 8 variables permit system behavior to be monitored and controlled at @@ -347,9 +341,6 @@ is adhered to. .Pp There are various other buffer-cache and VM page cache related sysctls. We do not recommend modifying these values. -As of -.Fx 4.3 , -the VM system does an extremely good job tuning itself. .Pp The .Va net.inet.tcp.sendspace @@ -547,30 +538,12 @@ and reboot the system. .Va kern.maxusers controls the scaling of a number of static system tables, including defaults for the maximum number of open files, sizing of network memory resources, etc. -As of -.Fx 4.5 , .Va kern.maxusers is automatically sized at boot based on the amount of memory available in the system, and may be determined at run-time by inspecting the value of the read-only .Va kern.maxusers sysctl. -Some sites will require larger or smaller values of -.Va kern.maxusers -and may set it as a loader tunable; values of 64, 128, and 256 are not -uncommon. -We do not recommend going above 256 unless you need a huge number -of file descriptors; many of the tunable values set to their defaults by -.Va kern.maxusers -may be individually overridden at boot-time or run-time as described -elsewhere in this document. -Systems older than -.Fx 4.4 -must set this value via the kernel -.Xr config 8 -option -.Cd maxusers -instead. .Pp The .Va kern.dfldsiz @@ -619,14 +592,6 @@ The option to .Xr netstat 1 may be used to observe network cluster use. -Older versions of -.Fx -do not have this tunable and require that the -kernel -.Xr config 8 -option -.Dv NMBCLUSTERS -be set instead. .Pp More and more programs are using the .Xr sendfile 2 @@ -705,11 +670,6 @@ can be used to monitor this. There are many solutions to saturated disks: increasing memory for caching, mirroring disks, distributing operations across several machines, and so forth. -If disk performance is an issue and you -are using IDE drives, switching to SCSI can help a great deal. -While modern -IDE drives compare with SCSI in raw sequential bandwidth, the moment you -start seeking around the disk SCSI drives usually win. .Pp Finally, you might run out of network suds. Optimize the network path @@ -718,10 +678,7 @@ For example, in .Xr firewall 7 we describe a firewall protecting internal hosts with a topology where the externally visible hosts are not routed through it. -Use 1000BaseT rather -than 100BaseT, depending on your needs. -Most bottlenecks occur at the WAN link (e.g.,\& -modem, T1, DSL, whatever). +Most bottlenecks occur at the WAN link. If expanding the link is not an option it may be possible to use the .Xr dummynet 4 feature to implement peak shaving or other forms of traffic shaping to
Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?201803182236.w2IMaLpF048520>