Date: Tue, 20 Apr 1999 21:28:07 +0200 From: sthaug@nethelp.no To: wilko@yedi.iaf.nl Cc: barry@lustig.com, stable@FreeBSD.ORG, scsi@FreeBSD.ORG Subject: Re: SCSI Failure during Amanda Backup (Unexpected busfree) Message-ID: <21146.924636487@verdi.nethelp.no> In-Reply-To: Your message of "Tue, 20 Apr 1999 20:18:34 %2B0200 (CEST)" References: <199904201818.UAA00793@yedi.iaf.nl>
next in thread | previous in thread | raw e-mail | index | archive | help
> > I am using all 3 SCSI connectors on the motherboard. The 50 pin connector > > Wrong. This is one SCSI bus as far as I can see. SCSI buses are linear > things, not star shaped. And they have only 2 terminators, each on every > end of the bus. What you may be missing here is that the ASUS P2B-DS has the Adaptec AIC 3860 bridge (as an option), which gives you an electrically isolated single-ended bus. So in this case, it should be possible to use all three connectors. Steinar Haug, Nethelp consulting, sthaug@nethelp.no To Unsubscribe: send mail to majordomo@FreeBSD.org with "unsubscribe freebsd-scsi" in the body of the message
Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?21146.924636487>