Date: Wed, 22 Apr 1998 07:40:37 -0400 From: Randall Hopper <rhh@ct.picker.com> To: scsi@FreeBSD.ORG Subject: uk0: extraneous data discarded ? Message-ID: <19980422074037.A23510@ct.picker.com> In-Reply-To: <19980418131605.A3370@ct.picker.com>; from Randall Hopper on Sat, Apr 18, 1998 at 01:16:05PM -0400 References: <19980418131605.A3370@ct.picker.com>
index | next in thread | previous in thread | raw e-mail
Trying to get my scanner (Microtek E6) working with -current and SANE. I'd
appreciate any tips those with more experience could provide.
The device probes up fine as uk0, Sane probes the device correctly as a
Microtek ScanMaker E6, but when Sane tries to scan with it, it gives:
scanimage: sane_start: Device busy
and this appears in /var/log/messages:
uk0: extraneous data discarded.
uk0: COMMAND FAILED (9 0) @f0551000.
What would be a good way to go about attacking this. I'm not a SCSI
expert, but willing to probe around.
Thanks,
Randall
Here are the particulars:
dmesg:
scbus0 target 6 lun 0: < Scanner 600 1.91> type 6 fixed SCSI 3
uk0 at scbus0 target 6 lun 0
uk0: Unknown
setenv SANE_DEBUG_MICROTEK 100; scanimage -d microtek:/dev/scanner
...
[microtek] sane_get_parameters...
[microtek] sane_get_parameters: res_code = 16 (10)
[microtek] sane_get_parameters: dots_per_mm: 3.937008
[microtek] sane_get_parameters: units_per_mm: 23.622047
[microtek] sane_get_parameters: lines: 0
[microtek] .wait_ready 3...
[microtek] .mode_select_1 3...
[microtek] .mode_sense_1...
scanimage: sane_start: Device busy <-----------------------
[microtek] sane_cancel...[microtek] sane_close...
[microtek] sane_exit...
[microtek] sane_exit: MICROTEK says goodbye.
Tail of SCSIDEBUG output for "scanimage -d microtek:/dev/scanner"
(enabled with "scsi -f /dev/uk0 -d 255"):
/kernel: uk0(ncr0:6:0): back from sleep
/kernel: uk0(ncr0:6:0): scsi_do_ioctl(0xc0605101)
/kernel: uk0(ncr0:6:0): user_strategy
/kernel: uk0(ncr0:6:0): scsi_cmd
/kernel: uk0(ncr0:6:0): get_xs
/kernel: uk0(ncr0:6:0): returning
/kernel: xs(0xf06fdf00): flg(0x828)sc_link(0xf06fde80)retr(0x0)timo(0xea60)cmd(0xf06fdf58)len(0x6)data(0xf3e75f8a)len(0x24)res(0x0)err(0
x0)bp(0xf0851d00)uk0: command: 19,0,0,0,1e,0-[36 bytes]
/kernel: ------------------------------
/kernel: 000: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
/kernel: 016: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 d0 4f
/kernel: 032: bf ef 75 a3
/kernel: ------------------------------
/kernel: uk0(ncr0:6:0): about to sleep
/kernel: uk0: extraneous data discarded. <---------------------
/kernel: uk0: COMMAND FAILED (9 0) @f0551000. <---------------------
/kernel: uk0(ncr0:6:0): scsi_done
/kernel: uk0: command: 19,0,0,0,1e,0-[36 bytes]
/kernel: ------------------------------
/kernel: 000: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
/kernel: 016: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 d0 4f
/kernel: 032: bf ef 75 a3
/kernel: ------------------------------
/kernel: uk0(ncr0:6:0): calling user done()
/kernel: uk0(ncr0:6:0): user-done
/kernel: uk0(ncr0:6:0): timeout <---------------------
/kernel: uk0(ncr0:6:0): returned from user done()
/kernel: uk0(ncr0:6:0): free_xs
/kernel: uk0(ncr0:6:0): returning to adapter
/kernel: uk0(ncr0:6:0): back from sleep
/kernel: uk0(ncr0:6:0): ukclose: Closing device
I notice that this is the the only occurance of "timeout" in the messages
output. Is this significant?
Regarding the "extraneous data discarded", I see in pci/ncr.c that this
occurs when (cp->xerr_status == XE_EXTRA_DATA), which seems to be set in a
script at the top. The comment for the set reference reads:
** The target wants to tranfer too much data
** or in the wrong direction.
** Remember that in extended error.
Do I need to bump buffer sizes or timeouts somewhere?
Sort of stabbing in the dark on this one, so anything you can suggest or
clarify would be appreciated.