References:  <20050529221024.4fu2p4yjusk04k0g@mail.banot.net>	<20050529212705.GA64753@xor.obsecurity.org>	<1117447400.5384.4.camel@localhost.localdomain>	<20050530104928.GB79877@sr.se>	<1117465224.9934.7.camel@localhost.localdomain>	<429B44BD.7070806@pp.nic.fi><20050530191843.GA82875@xor.obsecurity.org> <429B7DF6.8040704@it-is-warlock.de>

next in thread | previous in thread | raw e-mail | index | archive | help
----- Original Message ----- 
From: "Sebastian Ahndorf" <webmaster@it-is-warlock.de>


> Kris Kennaway wrote:
>>>Both sides must have same config, autosense should work if there is no 
>>>config possibility in other end.
>> 
>> autosense may in fact not work, especially on low-quality NICs like rl.
>> 
> 
> I don't agree to that.
> I had similar problems with my network using a cheap switch with some 
> realtek nics. I had the nics running 100baseTX Full Duplex.
> Changing this to autosense made the problems gone.
> 
> Reason (as some people of the german questions-list told me):
> Many cheap switches always send their autosensepakets, and have great 
> problems if the nics connected to the switch do not response to the 
> autosensepakets (cause they are configured to 10/100baseTX full/half 
> duplex).
> Also realtek nics are far away from being good nics, they work without 
> problems with the autosensemode and a cheap switch for me (and many 
> other people I know).
> 
> I would suggest the starter of this thread to use autosense with his nic 
> (if not tested yet).

Quite a few 100tx nic / switch combinations misbehave when both
sides are not set to the same be that 100fdx or auto sense. I've actually
never seen a problem with 100tx autoneg as long as both ends had
it selected and there wasn't a cable problem.