Hi!

> polling is almost never a performance advantage
> for ethernet, as virtually all modern controllers
> have some sort of interrupt moderation built-in.

We had the case on fbsd 5.4p7 with SMP where bge drivers produced
much slower throughput if we did not use polling. We measured using
ttcp and the difference was from 2-3Mbyte/sec to 11 Mbyte/sec.

Yes, it used more CPU, but for that increase in throughput, it
was worth the expense.

So it looks a bit strange from my part of the world to.

-- 
MfG/Best regards, Kurt Jaeger                                  15 years to go !
LF.net GmbH        fon +49 711 90074-23  pi@LF.net  
Ruppmannstr. 27    fax +49 711 90074-33
D-70565 Stuttgart  mob +49 171 3101372