Date: Sun, 03 Oct 1999 18:34:32 -0700 From: John Barbee <jbarbee@singular.com> To: freebsd-questions@freebsd.org Subject: vinum: faulty plex Message-ID: <4.1.19991003175604.00aa52c0@server7.singular.com>
next in thread | raw e-mail | index | archive | help
hi, i set up vinum about a week ago. i left it alone and just got back on track today. i imagine if things really are working one of my plexes wouldn't be faulty. i did a reset config but i still have a faulty plex. here is some output. did i do something wrong or is it one of my drives. silence# cat log NO VINOsilence.blackmist.orgsd0+89 ,8Vvolume mirror state up plex name mirror.p0 state up org concat vol mirror plex name mirror.p1 state faulty org concat vol mirror sd name mirror.p0.s0 drive sd0 state up len 4194304s driveoffset 265s plex mirror.p0 plexoffset 0s sd name mirror.p0.s1 drive sd1 state up len 4194304s driveoffset 265s plex mirror.p0 plexoffset 4194304s sd name mirror.p1.s0 drive sd2 state reviving len 4194304s driveoffset 265s plex mirror.p1 plexoffset 0s sd name mirror.p1.s1 drive sd3 state reviving len 4194304s driveoffset 265s plex mirror.p1 plexoffset 4194304s NO VINOsilence.blackmist.orgsd1+8Q ,8 volume mirror state up plex name mirror.p0 state up org concat vol mirror plex name mirror.p1 state faulty org concat vol mirror sd name mirror.p0.s0 drive sd0 state up len 4194304s driveoffset 265s plex mirror.p0 plexoffset 0s sd name mirror.p0.s1 drive sd1 state up len 4194304s driveoffset 265s plex mirror.p0 plexoffset 4194304s sd name mirror.p1.s0 drive sd2 state reviving len 4194304s driveoffset 265s plex mirror.p1 plexoffset 0s sd name mirror.p1.s1 drive sd3 state reviving len 4194304s driveoffset 265s plex mirror.p1 plexoffset 4194304s NO VINOsilence.blackmist.orgsd2+8 ,8 volume mirror state up plex name mirror.p0 state up org concat vol mirror plex name mirror.p1 state faulty org concat vol mirror sd name mirror.p0.s0 drive sd0 state up len 4194304s driveoffset 265s plex mirror.p0 plexoffset 0s sd name mirror.p0.s1 drive sd1 state up len 4194304s driveoffset 265s plex mirror.p0 plexoffset 4194304s sd name mirror.p1.s0 drive sd2 state reviving len 4194304s driveoffset 265s plex mirror.p1 plexoffset 0s sd name mirror.p1.s1 drive sd3 state reviving len 4194304s driveoffset 265s plex mirror.p1 plexoffset 4194304s NO VINOsilence.blackmist.orgsd3+8 ,85volume mirror state up plex name mirror.p0 state up org concat vol mirror plex name mirror.p1 state faulty org concat vol mirror sd name mirror.p0.s0 drive sd0 state up len 4194304s driveoffset 265s plex mirror.p0 plexoffset 0s sd name mirror.p0.s1 drive sd1 state up len 4194304s driveoffset 265s plex mirror.p0 plexoffset 4194304s sd name mirror.p1.s0 drive sd2 state reviving len 4194304s driveoffset 265s plex mirror.p1 plexoffset 0s sd name mirror.p1.s1 drive sd3 state reviving len 4194304s driveoffset 265s plex mirror.p1 plexoffset 4194304s To Unsubscribe: send mail to majordomo@FreeBSD.org with "unsubscribe freebsd-questions" in the body of the message
Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?4.1.19991003175604.00aa52c0>